We are retiring our old MSSQL 2005 server and moving the database over to a new 2012 server. How do I reconnect to my existing database on the new server without having to reinstall the Data Center Planner? I was told I would need to update the connection string after the move is complete, but I can't find any instructions for this in the administrators guide and I know next to nothing about Database Administration. Please help!!
↧
Forum Post: Data Center Planner - How do I change the connection string when upgrading the database server?
↧
Forum Post: Not Able to Dial in to ACS 6004
hi We recently bought 7 avocent ACS 6004 with internal modem. I am trying to set up dial in profile on Modem port When I dial out from the other side I am not getting any response. Line is working fine. what are the key points that need to be focused on my current configuration Aux port - Set dial in device name - ttyM1 Status - 115200 init Chat - ""\d\d\d+++\d\d\dATZ OK PPP address - Local configuration local ipv4 - 192.168.0.2 remote ipv4 - 192.168.0.1 PPP authentication - By Appliance protocol - PAP Chap-interval - 0 Chap-max challenge - 10 chap-restart - 3 ppp idle time-out - 0 Dial-in profile Login to Appliance - enable OTP Login Authentication - Disable PPP connection - enable PPP/PAP Authentication - Local (we are not using DSview) I have couple of Doubts 1) ACS 6004 is set for using IP from DHCP it currently in the LAB so it using default 192.168.160.10 does this IP addresses used for PPP connection should be from this subnet or it does not metter 2) Right now i have plugged in RJ11 connector in Modem port does it has to be RJ45 ?? 3) besides Above mentioned GUI setup do i need to make some changes elsewhere in order to enable the Internal modem 4) Is there anything wrong on the other side which should not be the case as i have tested the line using External modem instead of Internal modem OR in order to make connection with internal modem we need different kind of Setup on the other side Regards
↧
↧
Forum Post: ACS6048 - after firmware update, can't boot "no more processes left in this runlevel"
Hi, We are upgrading ACS6048 firmware from 2.2.0 to 2.5.0.12, but after execute the "flasImage" and reboot the OS, we can't boot the ACS. Always same option: Enter runlevel: X, INIT: Entering runlevel: X (where X is 0-6) Always same answer: INIT: no more processes left in this runlev We have tried to change bootimage from 2 to 1 and 1 to 2, but we have same situation. We are stuck in this point. How can we restore the OS? how we can restore /etc/inittab file? We only have access to u-boot menu and we can't establish any network connection. Could you help us? Thanks in advaced
↧
Forum Post: Configure a port using SNMP writable OID
Hello to all Through SNMP I configure a port of an ACS48 using the OID 1.3.6.1.4.1.2925.4.3 / 1.3.6.1.4.1.2925.4.2 , but when checking the data, they values are different if I check them through the GUI of the Appliance and the OID which OID value are represented in the DsVIEW? Best regards Gonzalo Arroyo
↧
Forum Post: Avocent Cyclades Alterpath ACS48
I have an Avocent Cyclades Alterpath ACS48, which I updated to firmware V_3.3.0-16 via the ACS Advanced Console Servers support page. 1. Is this the correct firmware for this device? It appears to run just fine. 2. Will this firmware be updated for the POODLE problem (I do not see it listed on your POODLE status page. 3. Is this the same firmware that runs the ACS5000 Console Server, which will be upgraded for POODLE? Thanks.
↧
↧
Wiki Page: ACS6000 MGETTY CONFIGURATION
ACS6000 MGETTY CONFIGURATION FIRWARE 3.0.0.11 and later Login to the appliance as root (default password linux) mgetty logs are configured on /etc/ mgetty+sendfax/mgetty.config [root@ACS6008-1122334488 /etc/mgetty+sendfax]# ls -la drwxr-xr-x 2 root root 0 Sep 16 19:25 . drwxr-xr-x 43 root root 0 Sep 19 19:53 .. -rw-r--r-- 1 root root 2718 Jul 16 22:37 login.config -rw-r--r-- 1 root root 1713 Sep 19 19:42 mgetty.config 2. Contents of mgetty.config below. Set debug to 8 for noisy log; you can try values in between. Default is “1”, which is no log. . . . . . . . . # set the global debug level to "1" (default from policy.h) debug 1 . . . . . . . . . 3.Configure the modem and reboot the appliance 4. The mgetty.ttyM1 log is gets created in /var/log/mgetty.ttyM1. Example follows for dialing into the ACS through internal modem. . . . . . . [root@ACS6008-1122334488 ~]# cd /var/log [root@ACS6008-1122334488 /var/log]# ls -la drwxr-xr-x 2 root root 120 Sep 20 01:31 . drwxr-xr-x 19 root root 420 Sep 20 01:29 .. -rw------- 1 root root 0 Sep 20 01:30 .linkup.dhcpc -rw------- 1 root root 981 Sep 20 01:29 dlog.log -rw------- 1 root root 24 Sep 20 01:32 faillog -rw------- 1 root root 2825 Sep 20 01:31 mgetty.ttyM1 [root@ACS6008-1122334488 /var/log]# cat mgetty.ttyM1 09/20 01:29:52 yM1 check for lockfiles 09/20 01:29:52 yM1 checklock: stat failed, no file 09/20 01:29:52 yM1 locking the line 09/20 01:29:52 yM1 makelock(ttyM1) called 09/20 01:29:52 yM1 do_makelock: lock='/var/lock/LCK..ttyM1' 09/20 01:29:52 yM1 lock made 09/20 01:29:52 yM1 tio_get_rs232_lines: status: RTS CTS DSR DTR 09/20 01:29:52 yM1 lowering DTR to reset Modem 09/20 01:29:53 yM1 tss: set speed to 38400 (017) 09/20 01:29:53 yM1 tio_set_flow_control( HARD ) 09/20 01:29:53 yM1 waiting for line to clear (VTIME=1), read: 09/20 01:29:53 yM1 send: \d\d\d+++\d\d\dATZ[0d] 09/20 01:29:56 yM1 waiting for ``OK'' 09/20 01:29:56 yM1 got: +++ATZ[0d] 09/20 01:29:56 yM1 CND: +++ATZ[0d][0a]OK ** found ** 09/20 01:29:56 yM1 waiting for line to clear (VTIME=3), read: [0d][0a] 09/20 01:29:56 yM1 removing lock file 09/20 01:29:56 yM1 waiting... 09/20 01:31:24 yM1 select returned 1 09/20 01:31:24 yM1 checking lockfiles, locking the line 09/20 01:31:24 yM1 makelock(ttyM1) called 09/20 01:31:24 yM1 do_makelock: lock='/var/lock/LCK..ttyM1' 09/20 01:31:24 yM1 lock made 09/20 01:31:24 yM1 wfr: waiting for ``RING'' 09/20 01:31:24 yM1 got: [0d][0a]RING[0d] 09/20 01:31:24 yM1 CND: RING 09/20 01:31:24 yM1 wfr: rc=0, drn=0 09/20 01:31:24 yM1 send: ATA[0d] 09/20 01:31:24 yM1 waiting for ``CONNECT'' 09/20 01:31:24 yM1 got: ATA[0d] 09/20 01:31:24 yM1 CND: OKATA[0d][0a]CONNECT ** found ** 09/20 01:31:43 yM1 send: 09/20 01:31:43 yM1 waiting for ``_'' 09/20 01:31:43 yM1 got: 38400[0d] 09/20 01:31:43 yM1 CND: CONNECT 38400 09/20 01:31:43 yM1 CND: found: 38400[0a] ** found ** 09/20 01:31:43 yM1 waiting for line to clear (VTIME=3), read: 09/20 01:31:43 yM1 looking for utmp entry... (my PID: 2187) 09/20 01:31:43 yM1 tio_set_flow_control( HARD ) 09/20 01:31:43 yM1 print welcome banner () 09/20 01:31:43 yM1 getlogname (FIDO AUTO_PPP), read:root[0d] 09/20 01:31:56 yM1 input finished with '\r', setting ICRNL ONLCR 09/20 01:31:56 yM1 tio_get_rs232_lines: status: RTS CTS DSR DTR DCD 09/20 01:31:56 yM1 login: use login config file /etc/mgetty+sendfax/login.config 09/20 01:31:56 yM1 match: user='root', key='' 09/20 01:31:56 yM1 match: user='root', key='' 09/20 01:31:56 yM1 match: user='root', key='' 09/20 01:31:56 yM1 login: version 2 09/20 01:31:56 yM1 match: user='root', key='*'*** hit! 09/20 01:31:56 yM1 login: utmp entry: /bin/false 09/20 01:31:56 yM1 looking for utmp entry... (my PID: 2187) 09/20 01:31:56 yM1 calling login: cmd='/bin/login', argv[]='login root' 09/20 01:31:56 yM1 setenv: 'CALLER_ID=none' 09/20 01:31:56 yM1 setenv: 'CONNECT=38400' 09/20 01:31:56 yM1 setenv: 'DEVICE=ttyM1' 09/20 01:31:56 ##### data dev=ttyM1, pid=2187, caller='none', conn='38400', name='', cmd='/bin/login', user='root'
↧
Forum Post: DCP4 SP6 or higher - Symbols and Licensing clarifications
1) What contains the device library received, starting from DCP SP6? All the devices created up to the point that DCP SP6 was released. 2) What will the customer receive together with the NEW DCP Versions (starting from SP6), downloaded directly from the Website? The latest DCP version will have symbols created by the Emerson Symbol’s Team only. Prior versions will have additional symbols but they cannot be used any longer as they were created by another Vendor. 3) As the customers would have to login to our Portal, prior to have access to the symbols, would they also have access to the “DCP Asset Listing”? Or, could this list be provided to the customer? Yes, when the User logs into the portal, there is a DCP Asset Listing located on their main Request Form. 4) What will gone happen with the Library Licenses that, till now, needed to be activated? On Avocent Data Center Planner R4, renewed maintenance also enables access to downloaded Symbols libraries or Symbol requests. If you can confirm that the user is having problems loading downloaded symbols: Identify the site (the ID will be needed to look up the state of the sites maintenance) Validate the issue Escalate the issue to Sustaining Engineering (L3) Sustaining engineering can engage the License Management team if there is an issue in loading symbols.
↧
Forum Post: How to update ACS 48 firmware
Hi, We are upgrading power servers firmware. ACS 6048 is not a problem but we have 4 old "ACS 48" servers and we can't find documentation related with how to update them. Here http://www.avocent.com/Services_and_Support/Customer_Support/Product_Updates/Product_Downloads_and_Updates.aspx and ACS6048. Do you know where can we find firmware and documentation related with how to upgrade the "ACS 48" servers? Thanks in advanced
↧
Forum Post: VGA solution for hmx2050 and hmiqdhdd
Hello, A client has hmx2050 and hmiqdhdd, but wants to connect the HMIQDHDD to a computer that has VGA only. I was told the CBL0076 / 0083 was the correct pigtail; may I add a DVI to VGA converter to one of the heads of the pigtail to make the VGA connection?
↧
↧
Forum Post: ACS48 banner and how to scape from a port session
Hi, We are upgrading ACS48 servers and we find some strange behaviour: Banners Under expert mode / network / hostsetting / general/ Console Banner, we have configured "TEST1" text and we can't see this banner while we are connecting to the console server. Same issue in port config /ports/physical ports/ Other/ Login Banner, we have configured "TEST2", but in this case we find another issue: - We can't see port banner "TEST2" and also - We can't close port session, we have to configure a little idle time value, because we can't escape the port session. In some web we can see that the escape sequence is "~~." but is not working in this case. Do you know if it is possible to change tihis sequence? Thanks in advance. Reards
↧
Forum Post: Unresponsive screen - Avocent Autoview 3008
Just today I have noticed that my Autoview 3008 is not responsive. I am getting green power lights on both the keyboard tray and on the power supply just behind it. However, the screen itself is black and there is no response to any of the controls on the screen itself (power, etc). I tried unplugging and reconnecting, and the power lights return as green, but again the screen has no response. With no other options, I tried temporarily unplugging the power adapter that lies directly behind the screen tray, and for a short time, the 'power' LED on the screen itself was blinking red, and I thought I saw a faint flicker of screen movement. THe power LED on the keyboard try remains green. Any suggestions as to what I am seeing here? My first thought was that perhaps the screen itself has failed, or something is wrong with the power to the display screen itself.
↧
RSA in Avocent Support
RSA in Avocent Support
↧
Forum Post: How to change postgres database password on newly installed server?
I have installed DSView 4.1 software on the server and created new postgres database. I have not configured DSView yet, I will be migrating from DSView 3.7 data from existing environment. I want to confirm/change postgres database password to match with other DSView servers, Can you please provide the steps to change password?
↧
↧
download dsview in Avocent Support
download dsview in Avocent Support
↧
UM SP discovery tool in Avocent Support
UM SP discovery tool in Avocent Support
↧
Forum Post: RRU commands
Does anyone know the Remote Reboot Unit (RRU) commands for Power on, Power off, or Toggle Power? Thanks in advance, Candace Pearson cpearson@newsbank.com
↧
Still Not connecting after downgrading the Java on my system to 7.51. Receiving the following errors: Please let me know if there is something else I can try… in Avocent Support
Still Not connecting after downgrading the Java on my system to 7.51. Receiving the following errors: Please let me know if there is something else I can try… in Avocent Support
↧
↧
Forum Post: SN of the TXs and RXs, within the HMXMGR WebUI
ISSUE: within the HMXMGR WebUI -> “Unit Identification Properties”, it is shown the EID of the TXs and RXs connected to the HMX Manager, and NOT the SN as it should RESOLUTION: The issue is that Serial Number is assigned after the manufacturing process, therefore it cannot be electronically added (will not be considered a FER) The work around is to use the unit Custom fields setting to trace the unit serial number (screenshot attached)
↧
Forum Post: MPU108EDAC - Cannot See Targets on Network
Hello all, We just purchased this MergePoint Unity unit and I'm having problems seeing the MPUIQ-VMCHS module that is attached to the KVM. When I'm logged onto the OBWI, the MPUIQ doesn't show up. If I connect to the KVM using a crossover cable connected to my laptop, I can see the MPUIQ no problem. This leads me to believe that something weird is going on with our network. the KVM and my laptop are connected to the same switch and is on the same VLAN. We are using a Dell N3048P switch. Perhaps the switch needs some sort of config change? Any help would be greatly appreciated.
↧
Forum Post: Help to get skills in the Trellis Platform
Hi Team, Please let me introduce myself, my name is Carlos Jimenez and I´m new in Emerson and obviously in the Trellis world. I´m taking some courses from the Emerson Network Power University portal, However, I have been trying to find any technical documentation (e.g. Installation guides, troubleshooting guides… etc). But not luck. On my first project I´ll have to perform a new Trellis implementation, and then upload data from a template. I just want to be ready for that. Maybe you can share with me some tips, knowledge or documents useful for my duties. I will be grateful for any help you can provide. Thanks, Carlos Jimenez
↧