Forum Post: UMG CLI Reference

$
0
0
Is there a PDF reference of the CLI for the UMG4000 appliance? It looks like there are a lot of things that can be done via that interface, likely much faster than through the web GUI, but I can't find a reference specific for the UMG, and I don't want to go poking around and end up breaking something without knowing how to fix it. things I'm looking for - rename targets ( especially PDU outlets ) - configure target connection options - delete a target and force the "re-discovery" of a specific port thanks, MJ

Forum Post: Vulnerabilities

$
0
0
Where can I find support for CVE resolution?

Wiki Page: UMG Recovery Methods

$
0
0
1) Rollack the UMG , to a previous version: - locally connected to UMG, with a Monitor / kb /mouse (using a serial connection would also work) - power cycle the unit - when the boot menu comes up, choose from the list the “earliest / oldest” FW version available - click ENTER and wait for the unit to reboot NOTE: This method will restore appliance functionality, without deleting / affecting its network configuration. The appliance can be upgraded afterwards, to the desired version. 2) Netboot recovery I MPORTANT: before starting this procedure, remove any physical and/or logical SP attached to the UMG !!! - u se a serial connection ( ADB0036 / DB9-RJ45 serial adapter and a CAT5/CAT6 straight cable) and an TFTP / FTP Server having the .ISO image uploaded on it - power cycle the unit - when the boot menu comes up, choose from the list the “Netboot recovery", and follow the procedure attached, in order to override unit's FW NOTE: This type of recovery will overwrite all firmware and configuration settings stored on the hard drives of the appliance and no data will be retained. 3) B oot from USB flash drive: this is basically an upgrade method, and works ONLY if you still have access to the console menu, while locally connected with a Monitor / kb / mouse - Format USB drive to FAT32 - Download and extract the UMG firmware to USB stick - Login into the UMG locally, default login admin /admin - ALT + F2 to switch to user shell - Insert USB stick with firmware into UMG - Select Option 5 from menu -> "Update Firmware"

Forum Post: UMG Recovery Methods

$
0
0
1) Rollack the UMG , to a previous version: - locally connected to UMG, with a Monitor / kb /mouse (using a serial connection would also work) - power cycle the unit - when the boot menu comes up, choose from the list the “earliest / oldest” FW version available - click ENTER and wait for the unit to reboot NOTE: This method will restore appliance functionality, without deleting / affecting its network configuration. The appliance can be upgraded afterwards, to the desired version. 2) Netboot recovery (please contact Tech Support for procedure and image file) I MPORTANT: before starting this procedure, remove any physical and/or logical SP attached to the UMG !!! - use a serial connection ( ADB0036 / DB9-RJ45 serial adapter and a CAT5/CAT6 straight cable) and an TFTP / FTP Server having the .ISO image uploaded on it - power cycle the unit - when the boot menu comes up, choose from the list the “Netboot recovery", and follow the procedure NOTE: This type of recovery will overwrite all firmware and configuration settings stored on the hard drives of the appliance and no data will be retained. 3) Boot from USB flash drive: this is basically an upgrade method, and works ONLY if you still have access to the console menu , while locally connected with a Monitor / kb / mouse - Format USB drive to FAT32 - Download and extract the UMG firmware to USB stick - Login into the UMG locally, default login admin /admin - ALT + F2 to switch to user shell - Insert USB stick with firmware into UMG - Select Option 5 from menu -> "Update Firmware"

Wiki Page: UMG Recovery Methods

$
0
0
(Please visit the site to view this file) 1) Rollack the UMG , to a previous version: - locally connected to UMG, with a Monitor / kb /mouse (using a serial connection would also work) - power cycle the unit - when the boot menu comes up, choose from the list the “earliest / oldest” FW version available - click ENTER and wait for the unit to reboot NOTE: This method will restore appliance functionality, without deleting / affecting its network configuration. The appliance can be upgraded afterwards, to the desired version. 2) Netboot recovery I MPORTANT: before starting this procedure, remove any physical and/or logical SP attached to the UMG !!! - use a serial connection ( ADB0036 / DB9-RJ45 serial adapter and a CAT5/CAT6 straight cable) and an TFTP / FTP Server having the .ISO image uploaded on it - power cycle the unit - when the boot menu comes up, choose from the list the “Netboot recovery", and follow the procedure attached, in order to ovewrite unit's FW NOTE: This type of recovery will overwrite all firmware and configuration settings stored on the hard drives of the appliance and no data will be retained. 3) Boot from USB flash drive: t his is basically an upgrade method, and works ONLY if you still have access to the console menu, while locally connected with a Monitor / kb / mouse - Format USB drive to FAT32 - Download and extract the UMG firmware to USB stick - Login into the UMG locally, default login admin /admin - ALT + F2 to switch to user shell - Insert USB stick with firmware into UMG - Select Option 5 from menu -> "Update Firmware"

Forum Post: CCM850 - SSH port change

$
0
0
Hi guys, Is there a way to change the default ssh port on CCM850 devices ? Thank you.

Hi I would like to know if the HMIQHDD transmitter include DVI/USB cables in Avocent Support

$
0
0
Hi I would like to know if the HMIQHDD transmitter include DVI/USB cables in Avocent Support

Wiki Page: Dsview End User License Agreement (EULA)

$
0
0
Introduction/Objective This document provides a Tech notes for finding the location of the Dsview End User License Agreement Problem Description Customer did not know where to find the EULA document for Dsview Solution The End User License Agreement for Dsview can be found: -During Dsview installation (user must acknowledge it before completing the installation) -At the bottom of Dsview login screen -In Dsview directory (webapp/help/en/eula.txt)

Wiki Page: DCP Database migration

$
0
0
Question: Can DCP migrate from a Microsoft SQL database to a Postgres database? Solution: DCP doesn’t support database migration cross different database platforms.

Forum Post: RE: Console Serial access on UMG 4000

$
0
0
Hi MJ which version of UMG is using ?

Forum Post: RE: Console Serial access on UMG 4000

$
0
0
Sorry for not including that info... 3.3.0.27 rdist is what shows for a version in the web ui.

Forum Post: RE: UMG CLI Reference

$
0
0
Hi MJ, Here's the link to the CLI Command reference guide. http://pcs.mktg.avocent.com/@@content/manual/5901127501b.pdf. All product technical documents can be found here: http://www.emersonnetworkpower.com/en-US/Support/Technical-Documents/kvm-switches/Pages/default.aspx regards,

Forum Post: RE: Console Serial access on UMG 4000

$
0
0
You mean that under the 3.3.0.27, you can not launch serial session by LDAP user, right ?

Forum Post: RE: Console Serial access on UMG 4000

$
0
0
I can launch a serial session, I just can't connect. If i authenticate to the UMG appliance with a username of "MJenne", when i try to launch a serial session the appliance is using the same username when trying to ssh into my network switch. I need the UMG device to NOT pass the username of the current user in the SSH session. MJ

Forum Post: RE: Console Serial access on UMG 4000

$
0
0
Hello Mj, I think at this stage you should open a case, as I think that is working as designed. But we can always test here and see what we find to work around your issue. Please contact support.avocent@emerson.com or call the support line for your local support center.

Forum Post: RE: CCM850 - SSH port change

$
0
0
Hi, The CCM SSH server operates only on the standard SSH port 22. Regards,

Forum Post: DSR 20135 Network Connect Error

$
0
0
I have several DSR2035's and have previously had to update firmware to compensate for old certificates and new versions of JAVA. It now seems they will not work at all with JAVA8+ I have tried the exceptions and changing the security settings in the ini file to no avail. I have the latest firmware. Can someone please point me in the right direction to get remote access re-enabled with JAVA8? Sorry if this is already posted somewhere, I looked but couldn't find anything..... TIA>

Forum Post: Trellis Upgrade Fail from 4.0.0 to 4.0.2

$
0
0
I am not able to upgrade trellis from 4.0.0 to 4.0.2 even though I have followed all instructions (pre-install and during installation). I am copying the screen log below; [ oracle@MZAMV1DCIM04 /u05/TrellisPatch-4.0.2] $ sh ./installPatch `/u01/trellis/trellis.version' -> `/u03/logs/installer//trellis.version.backed.by.4.0.2.20161026130005' `/u01/trellis/configuration.properties' -> `/u03/logs/installer//configuration.properties.backed.by.4.0.2.20161026130005' The base directory where the patch was expanded. Typically the same directory as where this script is being run. Type in the location for BASEDIR [/u05/TrellisPatch-4.0.2] :/u05/TrellisPatch-4.0.2 /u02/domains/IDMDomain /u05/TrellisPatch-4.0.2 ./installPatch: line 67: /u05/TrellisPatch-4.0.2/password.properties: Permission denied ./installPatch: line 68: /u05/TrellisPatch-4.0.2/password.properties: Permission denied /u05/TrellisPatch-4.0.2 existing JAVA_HOME= existing ANT_HOME= existing PATH=/u01/app/oracle/product/11.2.0/bin:/usr/lib64/qt-3.3/bin:/usr/local/bin:/bin:/usr/bin:/usr/local/sbin:/usr/sbin:/sbin:/home/oracle/bin existing ANT_OPTS= JAVA_HOME=/u01/jvm/jdk1.7.0_85 ANT_HOME=/u01/fm/11.1.1.7/modules/org.apache.ant_1.7.1 PATH=/u01/jvm/jdk1.7.0_85/bin:/u01/app/oracle/product/11.2.0/bin:/usr/lib64/qt-3.3/bin:/usr/local/bin:/bin:/usr/bin:/usr/local/sbin:/usr/sbin:/sbin:/home/oracle/bin:/u01/fm/11.1.1.7/modules/org.apache.ant_1.7.1/bin ANT_OPTS= -XX:+UseConcMarkSweepGC -XX:+CMSClassUnloadingEnabled -XX:PermSize=128m -XX:MaxPermSize=256m Apache Ant version 1.7.1 compiled on June 27 2008 java version "1.7.0_85" Java(TM) SE Runtime Environment (build 1.7.0_85-b15) Java HotSpot(TM) 64-Bit Server VM (build 24.85-b06, mixed mode) -- done setting up environment -- Buildfile: build.xml Trying to override old definition of task load-security-properties -recover-topology-document: BUILD FAILED /u05/TrellisPatch-4.0.2/build.xml:3875: condition satisfied Total time: 0 seconds [oracle@MZAMV1DCIM04 /u05/TrellisPatch-4.0.2] $ Your help is appreciated. Regards,

Forum Post: Cannot login to ACS6000 server.

$
0
0
When I attempt to log on at the console I get this: ACS6000 3.0.0.12-20141010 /dev/ttyS0 ************************************************************************ * WARNING! If you are not authorized to use this private network, * * please disconnect immediately. Unauthorized access is prohibited * * and will result in civil and/or criminal prosecution. Users * * expressly consent to having their activities monitored. * ************************************************************************ login: root Login incorrect login:

File: How to configure DSView 4.x to enable Single Sign-On with Kerberos

$
0
0
How to configure DSView 4 to enable Single Sign-On with SPNEGO and Kerberos 1.1 Register DSView server in the DNS 1.1.1 Requirements  DSView 4.x installed.
Viewing all 2025 articles
Browse latest View live